Measurement of Radiation Dose Received by the Eye Lens in Panoramic Examination Using a Thermoluminisence Dosimeter (TLD) in the Radiology Installation of Andalas University Hospital

Authors

  • Chairun Nisa Universitas Baiturrahmah
  • Wahdini Hanifah Universitas Baiturrahmah
  • Livia Ade Nansih Universitas Baiturrahmah
  • M.Biomed Universitas Baiturrahmah
  • Cicillia Artitin Universitas Baiturrahmah
  • Ananta Della Fitria Universitas Baiturrahmah

DOI:

https://doi.org/10.61942/msj.v4i2.594

Keywords:

Radiation Dose, Eye Lens, Panoramic, Thermoluminescence Dosimeter (TLD)

Abstract

A panoramic examination is an examination used to show the upper and lower jaws along with abnormalities in the oral area. The lens of the eye is a sensitive organ that is exposed to radiation during a panoramic examination. The lens of the eye that is exposed to radiation for a long time can cause cataracts that can develop to blindness, therefore to prevent cataracts, BAPETEN No. 6 of 2010 sets a deterministic threshold limit for the chance of cataracts at 15 mSv per year. This study aims to determine how much dose the lens of the eye receives during a panoramic examination and whether the dose received exceeds the established NBD. This type of research is an experimental quantitative study conducted at the Radiology Installation of Andalas University Hospital in September 2025 using a sample of 7 patients. The instruments and materials used are a panoramic machine, TLD and plaster isolation. Dose measurement is done by attaching the TLD to the patient's right and left eyelids then exposed using 73 kV, 10 mA and 10.8 s and then the TLD reading process is carried out. The measurement results obtained in nC units with the final result in the form of an effective dose compared with BAPETEN regulation No. 6 of 2010. The highest effective dose measurement result received by patient 2 was 0.13 mSv and the lowest in patient 1 was 0.095 mSv with an average dose received by all patients of 0.11 mSv. Based on BAPETEN regulation No. 6 of 2010, the deterministic threshold for the chance of cataracts is 15 mSv per year, so the range of effective dose values received by the patient is still within safe limits.

Downloads

Download data is not yet available.

References

Abdulhamid, M., Ibrahim, U., Zira, J., Yusuf, S., & Abdulhamid, A. (2022). Assessment of head CT protocol to reduce the radiation dose in eye lens in some selected hospital in Kaduna State, Nigeria.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine, 190, 110469. https://doi.org/10.1016/j.apradiso.2022.110469

Anam, C., Dewi, W., Masdi, M., Haryanto, F., Fujibuchi, T., & Dougherty, G. (2021). Investigation of Eye Lens Dose Estimate based on AAPM Report 293 in Head Computed Tomography. Journal of Biomedical Physics & Engineering, 11, 563 - 572. https://doi.org/10.31661/jbpe.v0i0.2104-1304

Basheer, B., Allahim, R., Alarfaj, S., Alkharashi, T., Fallatah, A., Alqahtani, A., & Aljarallah, S. (2021). Evaluation of Radiation Exposure in Open Dental Clinics Using Thermoluminescence Dosimeters and Questionnaires. Contemporary Clinical Dentistry, 12, 266 - 275. https://doi.org/10.4103/ccd.ccd_598_20

Endarko, E., Pitaloka, A., Inayah, A., Ramadhan, F., Kardianto, K., & Rahayuningsih, B. (2023). Evaluation of 3D Printed Anthropomorphic Head Phantom for Calibration of TLD in Eye Lens Dosimeter. Journal of Biomedical Physics & Engineering, 13, 193 - 202. https://doi.org/10.31661/jbpe.v0i0.2109-1401

Head of the Nuclear Energy Regulatory Agency. (2010). Regulation of the Head of the Nuclear Energy Regulatory Agency Number 6 of 2010 concerning Health Monitoring for Radiation Workers. Regulation of the Head of the Nuclear Energy Regulatory Agency Number 6 of 2010 concerning Health Monitoring for Radiation Workers.

Linda Ermiza. (2023). Legal Protection of the Use of Personal Protective Equipment (APRON) for Patients During Panoramic Radiological Examination. JISPENDIORA Journal of Social Sciences, Education, and Humanities, 1(1), 159-177. https://doi.org/10.56910/jispendiora.v1i1.574

Masdi (2013) 'Analysis of Radiation Dose Acceptance in the Eye Organ in Nasopharyngeal Examination Using CT Scan', Youngster Physics Journal.

Naserpour, F., Hassanpour, N., Panahi, F., Karami, V. and Gholami, M. (2019) 'An estimate of radiation dose to the lens of the eyes, parotid gland, and thyroid gland in dental panoramic radiography', Iranian Journal of Medical Physics, 16(6), pp. 425–429. doi: 10.22038/ijmp.2019.35929.1454 .

Özgür, E., Kayaokay, T., Özgür, D., Tünay, A., Günay, O., Kesmezacar, F., Demir, M., Almisned, G., & Tekin, H. (2026). Critical organ dose evaluation during interventional stroke imaging: Implications for radiation safety.. Radiography, 103331. https://doi.org/10.1016/j.radi.2026.103331

PERMENKES (2020) Regulation of the Minister of Health of the Republic of Indonesia Number 24 of 2020 concerning Clinical Radiology Services.

Reza, A., Hassan, J. and Adibi, A. (2018) 'Evaluation of radiation exposure of eyes, parotid and thyroid gland during panoramic radiography', African Journal of Internal Medicine, 6(7), pp. 488–494.

Seo, Y., & Yu, S. (2021). Thermoluminescent dosimetry of panoramic radiography. Oral Biology Research. https://doi.org/10.21851/obr.45.01.202103.22

Syafitri, NF, Milvita, D. and Kartikasari, D. (2024) 'Estimation of Enterance Surface Dose (ESD) on the Eye, Thyroid Gland, and Parotid Gland in Panoramic Dental Examination at Andalas University Hospital', Jurnal Fisika Unand, 13(3), pp. 385–391. doi: 10.25077/jfu.13.3.385-391.2024

Trikasjono, T., Hanifasari, K. and Suhendro, B. (2015) 'Analysis of Environmental Radiation Exposure in Radiology Rooms in Hospitals Using the Delphi Program', Journal of Electrical Technology, 6(3). doi: 10.22441/jte.v6i3.803.

Yunus, B., Bandu, K., Radiology, B., Program, M., Medicine, S., Medicine, F., & University, G. (2019). Effects of x-ray radiation on children. Makassar Dental Journal, 8(2), 97–104. https://doi.org/10. 35856/mdj.v8i2.278

Yusuf, K., Milvita, D., & Utami, H. (2023). The Impact of Radiation Dose Variation in Panoramic Dental Examination on Salivary Amylase Enzyme Activity. JURNAL ILMU FISIKA | UNIVERSITAS ANDALAS. https://doi.org/10.25077/jif.16.1.34-45.2024

Downloads

Published

15-05-2026

How to Cite

Nisa, C., Hanifah, W., Nansih, L. A., M.Biomed, Artitin, C., & Fitria, A. D. (2026). Measurement of Radiation Dose Received by the Eye Lens in Panoramic Examination Using a Thermoluminisence Dosimeter (TLD) in the Radiology Installation of Andalas University Hospital. MSJ : Majority Science Journal, 4(2), 77–87. https://doi.org/10.61942/msj.v4i2.594

Issue

Section

Articles