The Effect of Increment Reconstruction Variations in Ct-Scans of Head Trauma on the Contrast to Noise Ratio (CNR) in the Radiology Department of the Prof. Dr. M.A. Hanafiah General Hospital, SM Batusangkar
DOI:
https://doi.org/10.61942/msj.v4i2.578Keywords:
CT-Scan, head trauma, reconstruction increment, image quality, CNRAbstract
Computed Tomography (CT) is an essential imaging modality for evaluating head trauma due to its ability to provide detailed cross-sectional images. Image quality, particularly the Contrast to Noise Ratio (CNR), plays an important role in diagnostic accuracy. This study aimed to determine the effect of reconstruction increment variations on CNR values in head trauma CT examinations and to identify the increment that provides the most optimal image quality. This research was a quantitative experimental study conducted at the Radiology Unit of RSUD Prof. Dr. M.A. Hanafiah, SM Batusangkar, in February 2025. The population consisted of all patients who underwent CT brain examinations with clinical head trauma during the study period, totaling 12 patients, of whom five patients were selected as samples using purposive sampling. Secondary image data were reconstructed using two increment variations, 0.7 mm and 1 mm, with identical scanning parameters. CNR values were calculated using Radiant Viewer by measuring regions of interest (ROI), and the data were analyzed using the Shapiro–Wilk normality test followed by the Independent Samples T-Test. The results showed that the mean CNR value for the 0.7 mm increment was 304.52, which was higher than the 1 mm increment with a mean CNR of 288.51. However, statistical analysis demonstrated no significant difference between the two increment variations (p = 0.155; p > 0.05). In conclusion, both reconstruction increments produce comparable image quality in head trauma CT examinations. Nevertheless, the 0.7 mm increment provides higher CNR values and may be considered more optimal for improving image clarity
Downloads
References
A. Y. Bequet, L. Rusyadi, and F. Fatimah, “Nilai Contrast to Noise Ratio (CNR) Radiograf Thorax PA antara menggunakan Grid dengan tanpa Menggunakan Grid,” J. Imejing Diagnostik, vol. 6, no. 2, 2020, doi: 10.31983/jimed.v6i2.5653.
Dewilza, N. et al. (2024). Analysis Of Differences In Image Quality With Variations In Slice Thickness In Ct-Scan Brain Examinations With Trauma Cases At The Radiology Installation Of Rsi Siti Rahmah Padang. Jurnal Ilmu dan Teknologi Kesehatan. https://doi.org/10.33666/jitk.v15i2.643
Dewilza, N. and Yudha, S. (2023) Dasar-Dasar CT-Scan. Deepublish
Hutami, I. A. P. A., Sutapa, G. N., & Paramarta, I. B. A.(2021). Analisis Analisis Pengaruh Slice thickness Terhadap Kualitas Citra Pesawat CT Scan Di RSUD Bali Mandara. BULETIN FISIKA, 22(2), 77-83.
Kusumaningsih, L. P. R., Suryatika, I. B. M., Trisnawati, N. L. P., & Irhas, R, (2023). Pengaruh Variasi Slice Thickness Terhadap SNR dari Hasil Penyinaran CT-Scan di RSUP Prof. Dr. I. G. N. G Ngoerah. KPPA Journal, 7(2), 326-330.
Liliosa Miu, N., Instalasi Radiologi Rsud Bali Mandara, D., Putu Jeniyanthy, N. R., & Made Purwa Darmita Akademi Radiodiagnostik dan Radioterapi Bali, I. (2023). Analisis Variasi Penggunaan Increment Terhadap Informasi Citra Ct Scan Kepala Pada Kasus Stroke Non Hemoragic (SNH). 1(4), 1–09.
Manarisip, M. E. I., Oley, M. C., & Limpeleh, H. (2014). GAMBARAN CT SCAN KEPALA PADA PENDERITA CEDERA KEPALA RINGAN DI BLU RSUP Prof. Dr. R. D. KANDOU MANADO PERIODE 2012 – 2013. E-CliniC, 2(2), 1–6. https://doi.org/10.35790/ecl.2.2.2014.5100
Mutiara Fatimah Azhara, Syamsir Dewang, Dewi Astuty, S., & Ulfah Rosyidah. (2023). Analisis Modulation Transfer Function (Mtf) Dan Contras-To-Noise Ratio (Cnr) Untuk Optimasi Kualitas Citra Ct Scan. Berkala Fisika, 26(1), 1–7. https://ejournal.undip.ac.id/index.php/berkala_fisika/article/view/54919
Ningtias, D. R., Wahyudi, B., & Harsoyo, I. T. (2022). Comparative Test of the Effect of X-Ray Tube Current Analysis and Exposure Time on CR (Computed Radiography) Image Quality. Journal of Informatics and Telecommunication Engineering, 6(1), 267–275. https://doi.org/10.31289/jite.v6i1.7334
Putri, L. G. Y. R., Juliantara, I. P. E., & Darmita, I. M. P, (2023). The Effect Of Slice Thickness Variation On The Anatomical Information Of CT-Scan Paranasal Sinus Coronal Section In Clinical Rhinosinusitis. Jurnal Eduhealt,14(3),2808-4608)
Rachmani, A. A. D., Masrochah, S., & Mulyati, S. (2018). the Difference of Anatomical Information and Image Quality of Nasopharynx Carcinoma Ct Scan With Slice Thickness Variation on Axial Slice in Rsud Dr Moewardi Surakarta. Jurnal Imejing Diagnostik (JImeD), 4(2), 56. https://doi.org/10.31983/jimed.v4i2.3992
Searle, B., & Starkey, D. (2020). An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three-dimensional printed anatomical models constructed by fused deposition modelling. Journal of Medical Radiation Sciences, 67(1), 43–53. https://doi.org/10.1002/jmrs.382
Theresiani Dae, A.A Aris Diartama, & Made Purwa Darmita. (2023). Optimalisasi Kualitas Citra CT Scan Kepala Dengan Variasi Rekonstruksi Increment Pada Kasus Stroke Non Hemoragik Di Instalasi Radiologi RSAD TK II Udayana Denpasar. Compromise Journal : Community Proffesional Service Journal, 1(4), 11–17. https://doi.org/10.57213/compromisejournal.v1i4.33
Yudha S, Kes MT, Dewilza N, Rad AM, Kes MT. Radiografi Digital. Deepublish; 2023.
Zulvania Do Rego Jesus, I Putu Eka Juliantara, & I Kadek Sukadana. (2023). Perbandingan Kualitas Citra CT-Scan Kepala Pada Kasus Trauma Dengan Variasi Increment Di Rumah Sakit Balimed. Calory Journal : Medical Laboratory Journal, 1(4), 85–98. https://doi.org/10.57213/caloryjournal.v1i4.91
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Nerifa Dewilza, Oktavia Puspita Sari, Sagita Yudha, Balqis Maysan Farrahin

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.