EFFECTIVENESS TEST OF THE CT-SCAN ROOM AT THE RADIOLOGY DEPARTMENT OF SITI RAHMAH PADANG HOSPITAL

Authors

  • Cicillia Artitin Prodi Radiologi Fakultas Vokasi Universitas Baiturrahmah Padang, Sumatra Barat, Indonesia
  • Riri Kurnia Putri Prodi Radiologi Fakultas Vokasi Universitas Baiturrahmah Padang, Sumatra Barat, Indonesia
  • Chairun Nisa Prodi Radiologi Fakultas Vokasi Universitas Baiturrahmah Padang, Sumatra Barat, Indonesia

DOI:

https://doi.org/10.61942/msj.v4i1.531

Keywords:

CT-Scan Room, Effectiveness Test, Raysafe

Abstract

Radiation protection is a measure taken to reduce the harmful effects of radiation on health due to radiation exposure. The effectiveness of radiation protection in a room is an important factor in ensuring the safety of patients, healthcare workers, and the surrounding environment from unwanted radiation exposure. Field observations in the CT-Scan room are directly adjacent to other installations such as the NICU, chemodialysis, polyclinics, and patient waiting rooms. This study aims to evaluate the effectiveness of the walls, doors, and leaded glass of the CT-Scan room in blocking radiation according to national radiation safety standards. The study used an experimental quantitative method in the CT-Scan room of the Radiology Installation of RSI Siti Rahmah Padang on August 30, 2025 using a CT-Scan machine, a raysafe unforns X2 multimeter measuring instrument, a building meter measuring instrument and an air phantom. Measurement of the radiation dose rate at 12 different points, representing all components of the room structure, using exposure factors for the cranium, namely 130kv and 240 mAs. Measurements were made on the wall area leading to the surgical polyclinic, NICU room, control panel room, hemodialysis room, lead glass, and the main door, both from the inside and outside of the room. The effectiveness of radiation absorption was recorded in the range of 99.82% to 99.99%, with radiation passed less than 0.2% at all measurement points. The walls covered with 26 cm brick and 2 mm lead, as well as the doors and lead glass, were proven to meet and exceed the minimum effectiveness limit of 90% as stipulated by BAPETEN and the Indonesian Minister of Health Regulation. Thus, it can be concluded that the walls, doors, and lead glass of the CT-Scan room are effective in blocking radiation and have met radiation safety standards.

Downloads

Download data is not yet available.

References

Akhadi, M. (2000). Pengantar Proteksi Radiasi. Jakarta: BATAN.

Artitin, Cicillia. (2023). Biologi Radiasi. Deepublish https://books.google.co.id/books/about/Biologi_Radiasi.html?id=gww-EQAAQBAJ&redir_esc=y

Artitin, C., Dewilza, N., Yudha, S., & Fahmi, D. M. (2023). Gambaran Noise Pada Pemeriksaan CT-Scan Brain Menggunakan Protokol Fast Stroke. Jurnal Kesehatan Tambusai, 4(4), 6547–6549. https://pdfs.semanticscholar.org/01d9/b83b7a4e321e8818f9d591f7904aae337d0d.pdf

Artitin, C., Harahap, W. A., & Ellyanti, A. (2018). Pengukuran Dosis Radiasi Pada Organ Tiroid dan Mata Saat Pemeriksaan Fluroskopi. Jurnal Kesehatan Andalas, 8(2), 112–118. https://doi.org/10.25077/jka.v7i0.943

Badan Pengawas Tenaga Nuklir. (2005). Peraturan Kepala BAPETEN No. 1 Tahun 2005 tentang Keselamatan Radiasi. Jakarta: BAPETEN.

Badan Pengawas Tenaga Nuklir. (2010). Panduan Dosis Radiasi. Jakarta: BAPETEN.

Badan Pengawas Tenaga Nuklir. (2013). Peraturan Kepala BAPETEN No. 1 Tahun 2013 tentang Proteksi Radiasi dan Keselamatan Radiasi. Jakarta: BAPETEN.

Diky Triwahyuni. (2021). Interaksi Sinar-X dengan Materi. Jurnal Radiologi Medik, 3(1), 15–20.

Djatmiko, B. (2016). Keselamatan dan Kesehatan Kerja di Bidang Radiologi. Jakarta: Salemba Medika.

Ernawidiati. (2017). Pengertian Radiasi Pengion. Jurnal Kesehatan, 12(2), 89–94.

Fitriana, L., & Utami, H.S. (2021). Perbedaan Nilai Image Noise dan Dosis Radiasi dengan Menggunakan Automatic Exposure Control (AEC) pada Pemeriksaan CT-Scan. Jurnal Kesehatan, 12(2). 131-136. http://dx.doi.org/10.38165/jk.

Harahap, V., Saragih, J., & Ginting, E. B. (2025). Implementation of Radiation Protection Quality Control in Radiology Installations in Accordance with Ministry of Health Regulation No. 8 Of 2011. Metadata Journal, 5(3). https://doi.org/10.47652/metadata.v5i3.843

Joedoatmodjo, S. (1994). Dasar-dasar Fisika Radiasi. Jakarta: UI Press.

Kemenkes RI. (2020). Permenkes No. 24 Tahun 2020 tentang Persyaratan Bangunan dan Sarana Rumah Sakit. Jakarta: Kementerian Kesehatan Republik Indonesia.

Kusnita. (2021). Efek Produksi Pasangan dalam Radiologi. Jurnal Fisika Medis, 2(2), 45–50.

Martem, D. R. (2021). Efektivitas Shielding Radiasi pada Ruang Radiologi. Jurnal Proteksi Radiasi, 5(2), 45–52.

Notoatmodjo, S. (2012). Metodologi Penelitian Kesehatan. Jakarta: Rineka Cipta.

Nugheni, R. (2022). Efek Stokastik dan Deterministik Radiasi. Jurnal Radiologi Indonesia, 7(1), 32–38.

Peraturan Pemerintah RI. (2008). PP No. 29 Tahun 2008 tentang Perizinan Pemanfaatan Sumber Radiasi dan Bahan Nuklir. Jakarta: Sekretariat Negara.

Rahman, A. (2009). Fisika Radiologi. Bandung: Penerbit Medika.

Rojaya, R. (2024). Kesehatan dan Keselamatan Kerja di Instalasi Radiologi. Jurnal Keselamatan Kerja, 6(1), 11–19.

Septiyanti, E., dkk. (2020). Dasar-dasar Radiologi. Yogyakarta: Graha Ilmu.

Downloads

Published

19-02-2026

How to Cite

Artitin, C., Putri, R. K., & Nisa, C. (2026). EFFECTIVENESS TEST OF THE CT-SCAN ROOM AT THE RADIOLOGY DEPARTMENT OF SITI RAHMAH PADANG HOSPITAL. MSJ : Majority Science Journal, 4(1), 43–47. https://doi.org/10.61942/msj.v4i1.531