LINEARITY TEST ANALYSIS OF AIRCRAFT RADIATION OUTPUT X-RAY FLUOROSCOPY

Authors

  • Bambang Harianto Gunadarma University, Central Jakarta, Indonesia
  • Muhammad Kardaji Gunadarma University, Central Jakarta, Indonesia

DOI:

https://doi.org/10.61942/msj.v1i4.50

Keywords:

Linearity, Radiation Output, X-Rays, Fluoroscopy

Abstract

The number or intensity of X-ray photons produced correlates with the increase in tube current per time (mAs), which affects the image density on the final film. To ensure the consistency of the increase in X-ray radiation output and the Linear Coefficient of X-ray radiation output, is within the tolerance limits specified in PERKA BAPETEN Regulation Number 9 of 2011. The aim of this research is to determine the linearity of the X-ray Fluoroscopy radiation output in one of the houses. Jakarta sick. The method used is an experimental approach with a quantitative model. Measurement of radiation output using a PM1610 Personal Dosimeter on a Fluoroscopy aircraft. The results of measuring the linearity of X-ray radiation output with voltage variations of 40 kV, 50 kV, 60 kV, 70 kV show that the value of the Linearity Coefficient (CL) is (0.08 ; 0.06 ; 0.09 ; 0.07). So it can be said that the X-Ray Fluoroscopy equipment is in good condition because the CL value obtained in this study is below the Tolerance Limit Value according to PERKA BAPETEN Number 9 of 2011, namely CL ≤ 0.1 or ≤10%. This research can be carried out as a reference in further research

Downloads

Download data is not yet available.

References

Aizah, H. S. (2023). Pengaruh faktor eksposi terhadap dosis radiasi dan kualitas citra pesawat radiografi umum pada pemodelan phantom thoraks (Doctoral dissertation, Universitas Islam Negeri Maulana Malik Ibrahim).

Akhadi, M. (2020). Sinar-X Menjawab Masalah Kesehatan. Sleman : Deepublish CV. Budi Utama.

Anggraeni, L. (2020). Faktor-Faktor Yang Berhubungan Dengan Penggunaan Pocket Dosemeter Pada Petugas Radiologi di Instalasi Radiologi 9 Rumah Sakit B Andar Lampung. Jurnal Teras Kesehatan, 3(1), 70-85.

Dewilza, N., Rad, A. M., Kes, M. T., Yudha, S., & Kes, M. T. (2023). Dasar-Dasar CT-Scan. Sleman : Deepublish CV. Budi Utama.

Hidayah, N., Astari, F. M., Rad, T. R., & Fakhrurreza, M. (2021). Uji Kebocoran Tabung Pesawat Sinar-X Mobile Di Universitas ‘Aisyiyah Yogyakarta (Doctoral dissertation, Universitas ‘Aisyiyah Yogyakarta).

Hyperastuty, A. S., Mukhammad, Y., & Sugeng, S. (2021). Analisis Uji Kesesuaian Pesawat Sinar X Radiografi Mobile Merk Drgem Topaz-40d Menggunakan X-Ray Multimeter PIRANHA. Journal Of Health Science (Jurnal Ilmu Kesehatan), 6(1), 19-26.

Indah, NH, Dewang, S., & Astuty, S.D. (2023). Analisis Laju Dosis Keluaran Pesawat Sinar-X Fluoroskopi Dual Fungsi Di Rs Wahidin Sudirohusodo Makassar. Berkala Fisika , 26 (1), 8-14. https://ejournal.undip.ac.id/index.php/berkala_fisika/article/view/54922

Irsal, M., A. Targian., S. E. Wulandari., N. Kinasih. (2023). Perbandingan Dosis Radiasi Pemeriksaan Radiografi Thoraks PA Menggunakan Faktor Eksposi: Standar dan High kVp Berdasarkan Database DRL Si-INTAN BAPETEN. Jurnal Pengawasan Tenaga Nuklir Volume 3, Nomor 2.

Khoirot, R. M., Hakim, M. H., Alam, Y., & Ananingtyas, R. S. A. (2023). Analisis Nilai Drl Parameter Esak/Inak Pemeriksaan Thorax Ap/Pa X-Ray Canon. Journal of Science Nusantara, 3(2), 61-68.

Nuramdiani, D., Sarengat., I. Maulana. (2021). Tinjauan Densitas Radiograf Pada Berbagai Ketebalan Step Wedge Berbasis Variasi Arus Tabung. Jurnal Pendidikan Fisika Tadulako Online. Volume 9 No. 2.

Nurcahyo, P., & Aryani, A. I. (2023). Pelaksanaan Quality Control Pesawat Sinar X di Pelayanan Radiodiagnostik. JRI (Jurnal Radiografer Indonesia), 6(2), 61-64. https://doi.org/10.55451/jri.v6i2.152

Rani, R. (2020). Uji Akurasi Alat Ukur Radiasi Pada Kasus Kebocoran Tabung Pesawat Mobile X-Ray di BPFK Makassar (Doctoral dissertation, Universitas Hasanuddin).

Surachman. (2023). “Metode Estimasi Risiko Kanker Pada Organ Berisiko Pemeriksaan Radiografi Kepala di RSUD Kabupaten Bekasi Menggunakan Metode Monte Carlo”. Skripsi. Jakarta : Universitas Nasional.

Wiharja, U., & Al Bahar, A. K. (2019). Analisa Uji Kesesuaian Pesawat Sinar-X Radiografi. Prosiding Semnastek. https://jurnal.umj.ac.id/index.php/semnastek

Yufita, E., & Safitri, R. (2023). Analisa Pengaruh Faktor Eksposi Pesawat Sinar-X Terhadap Densitas Optik Film Radiografi. Jurnal Hadron, 5(01), 9-14.

Downloads

Published

29-12-2023

How to Cite

Harianto, B., & Kardaji, M. (2023). LINEARITY TEST ANALYSIS OF AIRCRAFT RADIATION OUTPUT X-RAY FLUOROSCOPY. MSJ : Majority Science Journal, 1(4), 1–5. https://doi.org/10.61942/msj.v1i4.50